    Electricians don’t want to touch DC circuits because it is illegal to mix low voltage DC and high voltage AC circuits. At least it’s illegal in Europe. You need to rebuild your walls to ensure separate and independent wiring channels. And that’s a very expensive nightmare.

    It’s a lot cheaper to buy Philips bulbs instead.

    • themeatbridge@lemmy.world
      link
      fedilink
      English
      arrow-up
      0
      ·
      edit-2
      16 days ago

      Yeah, I definitely get it. It would be illegal to mix low and line voltage in the USA, too.

      I ended up running the cabling myself, all class two circuits powering 12 24vdc spots. The nice bit is that they are all addressable RGBW spots, so I can control them all individually or as groups. And it’s all automated. The downside is that I’ll probably have to remove them if we ever sell this house, because nobody but me understands how it works.

      • Aux@lemmy.world
        link
        fedilink
        English
        arrow-up
        0
        ·
        16 days ago

        The thing is that it is a lot easier and a lot safer to buy some ESP32 boards, flash them with WLED, plug into 5V/12V/24V box, hide all of that in a 3D printed enclosure and call it a day than to rebuild the bloody walls (: And you won’t be breaking any regulations and every sparky will be fine with that.

        Running all your house with two wiring systems is dumb AF that’s why no one will ever do that for you. That’s my point.